AN INVERSE LINEARIZATION MODEL FOR THE CHARACTERIZATION OF NON-CONTACT THERMOPILES

Publications

Share / Export Citation / Email / Print / Text size:

International Journal on Smart Sensing and Intelligent Systems

Professor Subhas Chandra Mukhopadhyay

Exeley Inc. (New York)

Subject: Computational Science & Engineering, Engineering, Electrical & Electronic

GET ALERTS

eISSN: 1178-5608

DESCRIPTION

17
Reader(s)
50
Visit(s)
0
Comment(s)
0
Share(s)

VOLUME 9 , ISSUE 2 (June 2016) > List of articles

AN INVERSE LINEARIZATION MODEL FOR THE CHARACTERIZATION OF NON-CONTACT THERMOPILES

J-S. Botero V * / A. Salazar * / L-J. Morantes G. *

Keywords : Linearization, non-contact, thermopile, Peltier effect, thermistor.

Citation Information : International Journal on Smart Sensing and Intelligent Systems. Volume 9, Issue 2, Pages 637-650, DOI: https://doi.org/10.21307/ijssis-2017-888

License : (CC BY-NC-ND 4.0)

Received Date : 16-December-2015 / Accepted: 20-March-2016 / Published Online: 01-June-2016

ARTICLE

ABSTRACT

A thermopile is an electronic device that converts thermal energy into electrical energy by means of arrangements of thermocouples that are connected in series. In addition, optical filters restrict the wavelength that strikes the thermopile. One of the main advantages of using a thermopile is its sensitivity to infrared radiation, which allows implementing non-contact thermometers. However, the thermopile does not provide an absolute temperature value, but a value that is proportional to the temperature gradient between the local temperature in the measurement range of the thermopile and its internal temperature. Therefore, it is necessary to integrate temperature sensors aiming to correct the output temperature value. In this sense, the output of the thermopile corresponds to a value generated from the relationship between the internal temperature of the thermopile and the output temperature. This work proposes and evaluates a thermopile characterization model, which uses an incubation system and a thermoelectric cooling device to control the room temperature and the temperature that is read out using the thermopile, respectively. This is based on the automation of the data collection procedure and the characterization of the thermistor that is used to measure the temperature of the thermopile. The result is an experimental operating surface, from which a linearization model was derived.

Content not available PDF Share

FIGURES & TABLES

REFERENCES

[1] T. M. Adams and R. A. Layton, Introductory MEMS Fabrication and Applications. Springer Science+Business Media, 2010.
[2] J. Fraden, Handbook of Modern Sensors: Physics, Designs, and Applications, Fourth Ed. Springer New York, 2010.
[3] M. Assaad, I. Yohannes, A. Bermak, D. Ginhac, and F. Meriaudeau, “Design and characterization of automated color sensor system,” Int. J. smart Sens. Intell. Syst., vol. 7, no. 1, pp. 1–12, 2014.
[4] D. Bhattacharjee, G. Sharma, and R. Bera, “Universal intelligent sensor interface,” Int. J. Smart Sens. Intell. Syst., vol. 8, no. 4, pp. 2307–2327, 2015.
[5] J. Hughes, J. Yan, and S. Kenichi, “Development of Wireless Sensor Network Using Bluetooth Low Energy ( Ble ) for Construction,” Int. J. Smart Sens. Intell. Syst., vol. 8, no. 2, pp. 1379–1405, 2015.
[6] M. Liess, H. Karagözoglu, and H. Ernst, “Reducing thermal transient induced errors in thermopile sensors in ear thermometer applications,” Sensors Actuators A Phys., vol. 154, no. 1, pp. 1–6, Aug. 2009.
[7] G. Sun, T. Saga, T. Shimizu, Y. Hakozaki, and T. Matsui, “Fever screening of seasonal influenza patients using a cost-effective thermopile array with small pixels for close-range thermometry.,” Int. J. Infect. Dis. - IJID Off. Publ. Int. Soc. Infect. Dis., vol. 25, pp. 56–8, Aug. 2014.
[8] A. Mahajan, C. Oesch, H. Padmanaban, L. Utterback, and F. Figueroa, “Physical and Virtual Intelligent Sensors for Integrated Health Management Systems,” Int. J. Smart Sens. Intell. Syst., vol. 5, no. 3, pp. 559–575, 2012.
[9] J. Higuera-Guisset, J. Rodríguez-Viejo, M. Chacón, F. J. Muñoz, N. Vigués, and J. Mas, “Calorimetry of microbial growth using a thermopile based microreactor,” Thermochim. Acta, vol. 427, no. 1–2, pp. 187–191, Mar. 2005.
[10] S. a. O’Shaughnessy, M. a. Hebel, S. R. Evett, and P. D. Colaizzi, “Evaluation of a wireless infrared thermometer with a narrow field of view,” Comput. Electron. Agric., vol. 76, no. 1, pp. 59–68, Mar. 2011.
[11] R. I. Rodriguez and Y. Jia, “A wireless inductive-capacitive (L-C) sensor for rotating component temperature monitoring,” Int. J. Smart Sens. Intell. Syst., vol. 4, no. 2, pp. 325–337, 2011.
[12] K. Keränen, J.-T. Mäkinen, P. Korhonen, E. Juntunen, V. Heikkinen, and J. Mäkelä, “Infrared temperature sensor system for mobile devices,” Sensors Actuators A Phys., vol. 158, no. 1, pp. 161–167, Mar. 2010.
[13] A. Pesatori and M. Norgia, “Infrared image system for fire location,” Measurement, vol. 46, no. 10, pp. 4172–4178, Dec. 2013.
[14] S. P. Singh and P. Singh, “Effect of temperature and light on the growth of algae species: A review,” Renew. Sustain. Energy Rev., vol. 50, pp. 431–444, 2015.
[15] J.-S. Botero V., W. Hernandez, and E. Fernandez, “Orientation of a triaxial accelerometer using a homogeneous transformation matrix and Kalman filters,” Int. J. Smart Sens.iIntelligent Syst., vol. 7, no. 4, pp. 1631–1646, 2014.
[16] M. Kiani, S. H. Pourtakdoust, and A. A. Sheikhy, “Consistent calibration of magnetometers for nonlinear attitude determination,” Measurement, vol. 73, pp. 180–190, 2015.
[17] ASTM International, “E220-13, Standard Test Method for Calibration of Thermocouples By Comparison Techniques,” in Book of Standards, West Conshohocken, PA: ASTM International, 2013.
[18] C. Chen, Y.-K. Weng, and T.-C. Shen, “Performance evaluation of an infrared thermocouple.,” Sensors (Basel)., vol. 10, no. 11, pp. 10081–94, Jan. 2010.
[19] A. Chen and C. Chen, “Evaluation of piecewise polynomial equations for two types of thermocouples.,” Sensors (Basel)., vol. 13, no. 12, pp. 17084–97, Jan. 2013.
[20] N. Afsarimanesh and P. Z. Ahmed, “LabVIEW Based Characterization and Optimization of Thermal Sensors,” Int. J. Smart Sens. Intell. Syst., vol. 4, no. 4, pp. 726–739, 2011.
[21] X. C. Tong, Advanced Materials for Thermal Management of Electronic Packaging. Springer Science+Business Media, 2011.
[22] J. S. Steinhart and S. R. Hart, “Calibration curves for thermistors,” Deep Sea Res. Oceanogr. Abstr., vol. 15, no. 4, pp. 497–503, 1968.
[23] Oriental System Technology Inc. - Orisystech, “Thermopile Sensor OTP-538U,” Datasheet Oriental System Technology Inc., 2009. .
[24] Hebei, “Thermoelectric Cooler TEC1-12 706,” Datasheet Hebei I.T. (Shanghai) Co., Ltd. .

EXTRA FILES

COMMENTS