Intrapartum sonography – eccentricity or necessity?

Publications

Share / Export Citation / Email / Print / Text size:

Journal of Ultrasonography

Polish Ultrasound Society (Polskie Towarzystwo Ultrasonograficzne)

Subject: Medicine

GET ALERTS

ISSN: 2084-8404
eISSN: 2451-070X

DESCRIPTION

4
Reader(s)
9
Visit(s)
0
Comment(s)
0
Share(s)

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue / page

Related articles

VOLUME 15 , ISSUE 61 (June 2015) > List of articles

Intrapartum sonography – eccentricity or necessity?

Marzena Dębska * / Piotr Kretowicz / Romuald Dębski

Keywords : intrapartum ultrasound, digital examination, angle of progression, fetal head descent

Citation Information : Journal of Ultrasonography. Volume 15, Issue 61, Pages 125-136, DOI: https://doi.org/10.15557/JoU.2015.0011

License : (CC BY-SA 4.0)

Received Date : 26-February-2015 / Accepted: 07-April-2015 / Published Online: 13-September-2016

ARTICLE

ABSTRACT

Ultrasonography has been extensively used in obstetrics and gynecology since 1980’s.It found application in pediatric gynecology, procreation period, post-menopause, pregnancy monitoring and after delivery. Although the fi rst reports on the use of ultrasonography in assessing delivery mechanism were published in 1990’s, yet to date labor progress is evaluated by means of physical examination in most delivery units. Intrapartum sonography is not routinely performed despite the fact that numerous  studies documented high error rates of conventional obstetrical examination. Even an experienced physician makes a mistake in every third case of the fetal head descent and fontanelle position assessment. Nowadays, obstetrician’s role is not to strain for vaginal delivery at all costs,but to provide the patient in labor and her newborn with maximal safety. To achieve this objective, an obstetrician should distinguish between women who will deliver spontaneously and whose who require Cesarean section. Proper decision should be made on the basis of objective and valid evaluation of obstetric setting, which cannot be achieved solely with physical examination. Intrapartum sonography was shown to be far more accurate than digital examination. Moreover, it is not technically demanding, provides high reproducibility and neither increases the rate of ascending infection or causes discomfort to the patient. Current research suggests that if used routinely, intrapartum sonography can increase the safety of labor and reduce cesarean section rate.

Content not available PDF Share

FIGURES & TABLES

REFERENCES

1. Hayachi RH: Ultrasound uses in obstetrics. Clin Perinatol 1983; 10: 253–261.

2. Akmal S, Tsoi E, Kametas N, Howard R, Nicolaides KH: Intrapartum sonography to determine the fetal head position. J Matern Fetal Neonatal  Med 2002; 12: 172–177.

3. Sherer DM, Miodovnik M, Bradley KS, Langer O: Intrapartum fetal head position I: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the active stage of labor. Ultrasound Obstet Gynecol 2002; 19: 258–263.

4. Sherer DM, Miodovnik M, Bradley KS, Langer O: Intrapartum fetal head position II: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the second stage of labor. Ultrasound Obstet Gynecol 2002; 19: 264–268.

5. Souka AP, Haritos T, Basayiannis K, Noikokyri N, Antsaklis A: Intrapartum ultrasound for the examination of the fetal head position in normal and obstructed labor. J Matern Fetal Neonatal Med 2003;13: 59–63.

6. Dupuis O, Silveira R, Zentner A, Dittmar A, Gaucherand P, Cucherat M et al.: Birth simulator: reliability of transvaginal assessment of fetal head station as defi ned by the American College of Obstetricians and Gynecologists classifi cation. Am J Obstet Gynecol 2005; 192: 868–874.

7. Akmal S, Kametas N, Tsoi E, Hargreaves C, Nicolaides KH: Comparison of transvaginal digital examination with intrapartum sonography to determine fetal head position before instrumental delivery. Ultrasound Obstet Gynecol 2003; 21: 437–440.

8. Sherer DM, Onyeije CI, Bernstein PS, Kovacs P, Manning FA: Utilization of real-time ultrasound on labor and delivery in an active academic teaching hospital. Am J Perinatol 1999; 16: 303–307.

9. Chou MR, Kreiser D, Taslimi MM, Druzin ML, El-Sayed YY: Vaginal versus ultrasound examination of fetal occiput position during the second stage of labor. Am J Obstet Gynecol 2004; 191: 521–524.

10. Akmal S, Tsoi E, Nicolaides KH: Intrapartum sonography to determine fetal occipital position: interobserver agreement. Ultrasound Obstet Gynecol 2004; 24: 421–424.

11. Rozenberg P, Porcher R, Salomon LJ, Boirot F, Morin C, Ville Y: Comparison of the learning curves of digital examination and transabdominal sonography for the determination of fetal head position during labor.Ultrasound Obstet. Gynecol. 2008; 31: 332–337. 

12. Barbera AF, Pombar X, Perugino G, Lezotte DC, Hobbins JC: A new method to assess fetal head descent in labor with transperineal ultrasound. Ultrasound Obstet             Gynecol 2009; 33: 313–319.  

13. Dückelmann AM, Bamberg C, Michaelis SA, Lange J, Nonnenmacher A, Dudenhausen JW, Kalache KD: Measurement of fetal head descent using the ‘angle of progression’ on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise. Ultrasound Obstet. Gynecol. 2010; 35: 216–222.

14. Tutschek B, Torkildsen EA, Eggebø TM: Comparison between ultrasound parameters and clinical examination to assess fetal head station in labor. Ultrasound Obstet Gynecol 2013; 41: 425–429.

15. Henrich W, Dudenhausen J, Fuchs I, Kämena A, Tutschek B: Intrapartum translabial ultrasound (ITU): sonographic landmarks and correlation with successful vacuum extraction. Ultrasound Obstet Gynecol 2006; 28: 753–760.

16. Eggebø TM, Hassan WA, Salvesen KÅ, Lindtjørn E, Lees CC: Sonographic prediction of vaginal delivery in prolonged labor: a two-center study. Ultrasound Obstet Gynecol 2014; 43: 195–201.

17. Torkildsen EA, Salvesen KÅ, Eggebø TM: Prediction of delivery mode with transperineal ultrasound in women with prolonged fi rst stage of labor. Ultrasound Obstet. Gynecol. 2011; 37: 702–708.

18. Ghi T, Youssef A, Maroni E, Arcangeli T, De Musso F, Bellussi F et al.: Intrapartum transperineal ultrasound assessment of fetal head progression in active second stage of labor and mode of delivery. Ultrasound Obstet Gynecol 2013; 41: 430–435. 

19. Cuerva MJ, Bamberg C, Tobias P, Gil MM, De La Calle M, Bartha JL: Use of intrapartum ultrasound in the prediction of complicated operative forceps delivery of fetuses in non-occiput posterior position. Ultrasound Obstet Gynecol 2014; 43: 687–692.

20. Youssef A, Maroni E, Ragusa A, De Musso F, Salsi G, Iammarino MT et al.: Fetal head-symphysis distance: a simple and reliable ultrasound index of fetal head station in labor. Ultrasound Obstet Gynecol 2013; 41: 419–424.

21. Ghi T, Maroni E, Youssef A, Morselli-Labate AM, Paccapelo A, Montaguti E: Sonographic pattern of fetal head descent: relationship with duration of active second stage of labor and occiput position at delivery.Ultrasound Obstet Gynecol 2014; 44: 82–89.

22. Eggebø TM, Heien C, Økland I, Gjessing LK, Romundstad P, Salvesen KA: Ultrasound assessment of fetal head-perineum distance before induction of labor. Ultrasound Obstet Gynecol 2008; 32: 199–204.

23. Ghi T, Farina A, Pedrazzi A, Rizzo N, Pelusi G, Pilu G: Diagnosis of station and rotation of the fetal head in the second stage of labor with intrapartum translabial ultrasound. Ultrasound Obstet Gynecol 2009; 33: 331–336.

24. Hassan WA, Eggebø TM, Ferguson M, Lees C: Simple two-dimensional ultrasound technique to assess intrapartum cervical dilatation: a pilot study. Ultrasound Obstet Gynecol 2013; 41: 413–418.

25. Gilboa Y, Kivilevitch Z, Spira M, Kedem A, Katorza E, Moran O et al.: Pubic arch angle in prolonged second stage of labor: clinical signifi - cance. Ultrasound Obstet Gynecol 2013; 41: 442–446.

26. Blasi I, D’Amico R, Fenu V, Volpe A, Fuchs I, Henrich W et al.: Sonographic assessment of fetal spine and head position during the fi rst and second stages of labor for the diagnosis of persistent occiput posterior position: a pilot study. Ultrasound Obstet Gynecol 2010; 35: 210–215. 

27. Gilboa Y, Kivilevitch Z, Spira M, Kedem A, Katorza E, Moran O et al.: Head progression distance in prolonged second stage of labor: relationship with mode of delivery and fetal head station. Ultrasound Obstet Gynecol 2013; 41: 436–441.

28. Hassan WA, Eggebø T, Ferguson M, Gillett A, Studd J, Pasupathy D et al.: The sonopartogram: a novel method for recording progres of labour by ultrasound. Ultrasound Obstet Gynecol 2014; 43: 189–194.

29. Cunningham F, Leveno KJ, Bloom SI, Hauth JC, Gilstrap JC (eds.): Williams Obstetrics. Vol. 1, McGraw-Hill 2005; 15–38.

30. Dückelmann AM, Michaelis SA, Bamberg C, Dudenhausen JW, Kalache KD: Impact of intrapartal ultrasound to assess fetal head position and station on the type of obstetrical interventions at full cervical dilatation.J Matern Fetal Neonatal Med 2012; 25: 484–488.

EXTRA FILES

COMMENTS