Search

  • Select Article Type
  • Abstract Supplements
  • Blood Group Review
  • Call to Arms
  • Hypothesis
  • In Memoriam
  • Interview
  • Introduction
  • Short Report
  • abstract
  • Abstracts
  • Article
  • book-review
  • case-report
  • case-study
  • Clinical Practice
  • Commentary
  • Conference Presentation
  • conference-report
  • congress-report
  • Correction
  • critical-appraisal
  • Editorial
  • Editorial Comment
  • Erratum
  • Events
  • Letter
  • Letter to Editor
  • mini-review
  • minireview
  • News
  • non-scientific
  • Obituary
  • original-paper
  • Original Research
  • Pictorial Review
  • Position Paper
  • Practice Report
  • Preface
  • Preliminary report
  • Product Review
  • rapid-communication
  • Report
  • research-article
  • Research Communicate
  • research-paper
  • Research Report
  • Review
  • review -article
  • review-article
  • review-paper
  • Review Paper
  • Sampling Methods
  • Scientific Commentary
  • short-communication
  • short-report
  • Student Essay
  • Varia
  • Welome
  • Select Journal
  • Architecture Civil Engineering Environment

 

research-article | 30-November-2017

THERMAL IMPROVEMENT IN RESIDENTIAL BUILDINGS IN VIEW OF THE INDOOR AIR QUALITY – CASE STUDY FOR POLISH DWELLING

was not subject of indoor air quality and airtightness measurement) is 72.5 m2. The apartment is equipped with an airtight windows, without trickle vents. Thermal improvements were carried out in 2011. Table 2 contains information about the rooms where the measurements were carried out. Table 2. Room characteristics No of room Kind of room Area Volume Characteristic m2 m3 01 room 1 11.10 27.75 Student’s living-room and bedroom. The door is often closed. Heated in wintertime

Monika BLASZCZOK, Andrzej BARANOWSKI

Architecture, Civil Engineering, Environment, Volume 11 , ISSUE 3, 121–130

Article | 26-August-2018

COOLING DEMAND IN MUSEUM PREMISES – NUMERICAL PREDICTION AND MEASUREMENT VALIDATION

The paper presents the results of identification and assessment of the energy demand for cooling purposes in the museum building. The analysis of cooling demand and assessment of indoor air quality were performed by the simulation analysis and validated by the measurement campaign of the indoor air quality in the building under consideration. For the purpose of thermal analysis the IDA ICE software was used. All simulations were carried out using meteorological data recorded by the local

Joanna FERDYN-GRYGIEREK, Andrzej BARANOWSKI

Architecture, Civil Engineering, Environment, Volume 9 , ISSUE 2, 125–135