Search

  • Select Article Type
  • Abstract Supplements
  • Blood Group Review
  • Call to Arms
  • Communications
  • Hypothesis
  • In Memoriam
  • Interview
  • Introduction
  • Letter to the Editor
  • Short Report
  • abstract
  • Abstracts
  • Article
  • book-review
  • case-report
  • case-study
  • Clinical Practice
  • Commentary
  • Conference Presentation
  • conference-report
  • congress-report
  • Correction
  • critical-appraisal
  • Editorial
  • Editorial Comment
  • Erratum
  • Events
  • in-memomoriam
  • Letter
  • Letter to Editor
  • mini-review
  • minireview
  • News
  • non-scientific
  • Obituary
  • original-paper
  • original-report
  • Original Research
  • Pictorial Review
  • Position Paper
  • Practice Report
  • Preface
  • Preliminary report
  • Product Review
  • rapid-communication
  • Report
  • research-article
  • Research Communicate
  • research-paper
  • Research Report
  • Review
  • review -article
  • review-article
  • review-paper
  • Review Paper
  • Sampling Methods
  • Scientific Commentary
  • serologic-method-review
  • short-communication
  • short-report
  • Student Essay
  • Varia
  • Welome
  • Select Journal
  • Polish Journal Of Microbiology
  • In Jour Smart Sensing And Intelligent Systems

 

original-paper | 05-December-2019

Structural Changes of Bacillus subtilis Biomass on Biosorption of Iron (II) from Aqueous Solutions: Isotherm and Kinetic Studies

; Cai et al. 2018). Besides, many studies reported the biosorption of iron by various microbial biosorbents (Keshtkar et al. 2016; Migahed et al. 2017). However, there is very little information regarding the structural and functional changes occurring on the biomass of B. subtilis as a consequence of iron biosorption. Hence, in the present study iron removal was done by utilizing biomass of B. subtilis in aqueous solutions. Optimization of experimental parameters, isotherms, and kinetic studies was

SRI LAKSHMI RAMYA KRISHNA KANAMARLAPUDI, SUDHAMANI MUDDADA

Polish Journal of Microbiology, Volume 68 , ISSUE 4, 549–558

Article | 01-June-2016

ERRORS OF MANOMETRIC CO2 SORPTION EXPERIMENTS ON COAL CAUSED BY ACCURACY OF PRESSURE SENSOR

The accuracy of supercritical CO2 sorption determination on coal is important for estimating the CO2 sequestration potential of coal bed using CO2 injection into deep unminable coal seams. Based on the CO2 density change and CO2 sorption data of three selected coal samples, this paper investigates the effect of pressure-sensor accuracy on measurements of CO2 adsorption isotherms on coals with manometric equipment. The characteristic density-change of CO2 in proper pressure range determines a

Jiang Renxia, Yu Hongguan, Wang Li, Chen Lihui

International Journal on Smart Sensing and Intelligent Systems, Volume 9 , ISSUE 2, 468–490

No Record Found..
Page Actions